Technical Data
Main Features
EFI00218
2.712593
EFI07515
-13|131
EFI07337
0.0015|0.0387
EFI07343
0.0015|0.0248
Voltage type
AC
Built-in depth
68.9 mm
Rated current
6 A
Rated voltage
240 V
Release characteristic
B
Rated insulation voltage Ui
500 V
Rated fault current
0.03 A
Leakage current type
A
Surge current capacity
0.25 kA
Current limiting class
3
Over voltage category
3
Pollution degree
2
Width in number of modular spacings
1
Frequency
50/60 Hz
Degree of protection (IP)
IP20
Number of protected poles
1
Concurrently switching neutral conductor
no
Rated short-circuit breaking capacity according to IEC 60947-2
-
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
With interlocking device
yes
Ambient temperature during operating
-25 - 55 °C
Flush-mounted installation
no
Number of poles (total)
2
Anti-nuisance tripping version
no
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA
Disconnection characteristic
Undelayed
Rated short-circuit breaking capacity according to EN 61009
6 kA
Downloads

Residual Current Circuit Breaker with Overcurrent Protection
Product details
SKU Code: 2CSR255151R1065
EAN Code: 8012542399629
Minimum order: 1
Available for Back Order (3 sellers)
Availability
Back Order Call for availability on 0345 030 60 80
£71.77
Back Order Manufacturer lead time of 7 weeks.
£60.21
Back Order
£62.11
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Back Order Call for availability on 0345 030 60 80 | £71.77 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 7 weeks. | £60.21 Ex. VAT | |
![]() |
Back Order | £62.11 Ex. VAT |
Price Range:
£60.21 > £71.77 ex. vat
17 loyalty points
Technical Data
Main Features
EFI00218
2.712593
EFI07515
-13|131
EFI07337
0.0015|0.0387
EFI07343
0.0015|0.0248
Voltage type
AC
Built-in depth
68.9 mm
Rated current
6 A
Rated voltage
240 V
Release characteristic
B
Rated insulation voltage Ui
500 V
Rated fault current
0.03 A
Leakage current type
A
Surge current capacity
0.25 kA
Current limiting class
3
Over voltage category
3
Pollution degree
2
Width in number of modular spacings
1
Frequency
50/60 Hz
Degree of protection (IP)
IP20
Number of protected poles
1
Concurrently switching neutral conductor
no
Rated short-circuit breaking capacity according to IEC 60947-2
-
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
With interlocking device
yes
Ambient temperature during operating
-25 - 55 °C
Flush-mounted installation
no
Number of poles (total)
2
Anti-nuisance tripping version
no
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA
Disconnection characteristic
Undelayed
Rated short-circuit breaking capacity according to EN 61009
6 kA
Downloads