ABB

Miniature Circuit Breaker - S200M - 3P - 6 A - D

System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space.

Product details

SKU Code: 2CDS273001R0061

EAN Code: 4016779600972

Minimum order: 1

Good Availability (3 sellers)

Availability

City Electrical Factors

5 In Stock

£87.70

Control Components Anglia

Back Order Call for availability on 0345 030 60 80

£107.07

RS Components

1 In Stock

£91.78

Distributor Availability Price  
City Electrical Factors 5 In Stock £87.70 Ex. VAT
Control Components Anglia Back Order Call for availability on 0345 030 60 80 £107.07 Ex. VAT
RS Components 1 In Stock £91.78 Ex. VAT

Price Range:

£87.70 > £107.07 ex. vat

Technical Data

Main Features

EFI00218

2.71653

EFI07515

-13|131

EFI07337

0.0011|0.0542

EFI07343

0.0011|0.0387

Voltage type

Other

Built-in depth

69 mm

Rated current

6 A

Rated voltage

400 V

Frequency

50 - 60 Hz

Release characteristic

D

Rated insulation voltage Ui

440 V

Current limiting class

3

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

3.0

Explosion-proof

no

Degree of protection (IP)

IP20

Number of protected poles

3

Concurrently switching neutral conductor

no

Connectable conductor cross section solid-core

0.75 - 35 mm²

Connectable conductor cross section multi-wired

0.75 - 25 mm²

Ambient temperature during operating

-25 - 55 °C

Flush-mounted installation

no

Additional equipment possible

yes

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10 kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25 kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15 kA

Rated impulse withstand voltage Uimp

4 kV