Technical Data
Main Features
EFI08827
0.03875007750015500031000062
EFI08828
0.0248000496000992001984003968
Mounting method
Other
With remote signalling contact
yes
Number of conductors (without earthing)
3
Construction size
3 modular spacing
Voltage protection level
-
Max. continuous voltage AC
1100 V
Nominal discharge surge current (8/20)
10 kA
Nominal voltage AC
690 V
Nominal voltage DC
-
Category type 2
no
Voltage protection level L-N
-
Signalling at the device
Optical
Max. continuous voltage DC
-
Degree of protection (IP)
IP20
Max. PV-voltage
-
Voltage protection level N-PE
2 kV
Integrated backup fuse
no
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
16 mm²
System configuration DC
no
System configuration IT
yes
System configuration TN
yes
System configuration TN-C
yes
System configuration TN-S
no
System configuration TT
no
System configuration other
yes
System configuration TN-C-S
no
Max. discharge surge current (8/20)
10 kA
Short-circuit breaking capacity (Isccr)
100 kA
Max. overcurrent protection device, parallel connection (fuse)
-
Max. overcurrent protection device, series connection (fuse)
100 A
Integrated short-circuit protection
no
Integrated short-circuit protection selective to fuse gG
-
Leakage-current free
no
Downloads

Surge Protective Device
Product details
SKU Code: 2CTB802345R3300
EAN Code: 3660308518682
Minimum order: 1
Available for Back Order (3 sellers)
Availability
Back Order Call for availability on 0345 030 60 80
£219.20
Back Order Manufacturer lead time of 7 weeks.
£182.67
Back Order
£464.63
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Back Order Call for availability on 0345 030 60 80 | £219.20 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 7 weeks. | £182.67 Ex. VAT | |
![]() |
Back Order | £464.63 Ex. VAT |
Price Range:
£182.67 > £464.63 ex. vat
104 loyalty points
Technical Data
Main Features
EFI08827
0.03875007750015500031000062
EFI08828
0.0248000496000992001984003968
Mounting method
Other
With remote signalling contact
yes
Number of conductors (without earthing)
3
Construction size
3 modular spacing
Voltage protection level
-
Max. continuous voltage AC
1100 V
Nominal discharge surge current (8/20)
10 kA
Nominal voltage AC
690 V
Nominal voltage DC
-
Category type 2
no
Voltage protection level L-N
-
Signalling at the device
Optical
Max. continuous voltage DC
-
Degree of protection (IP)
IP20
Max. PV-voltage
-
Voltage protection level N-PE
2 kV
Integrated backup fuse
no
Max. conductor cross section solid (solid, stranded)
25 mm²
Max. conductor cross section flexible (fine-strand)
16 mm²
System configuration DC
no
System configuration IT
yes
System configuration TN
yes
System configuration TN-C
yes
System configuration TN-S
no
System configuration TT
no
System configuration other
yes
System configuration TN-C-S
no
Max. discharge surge current (8/20)
10 kA
Short-circuit breaking capacity (Isccr)
100 kA
Max. overcurrent protection device, parallel connection (fuse)
-
Max. overcurrent protection device, series connection (fuse)
100 A
Integrated short-circuit protection
no
Integrated short-circuit protection selective to fuse gG
-
Leakage-current free
no
Downloads