Technical Data
Main Features
Voltage type
AC
Built-in depth
72 mm
Rated current
16 A
Rated voltage
240 V
Release characteristic
C
Rated insulation voltage Ui
400 V
Rated fault current
0.03 A
Leakage current type
A
Surge current capacity
0.25 kA
Current limiting class
3
Over voltage category
2
Pollution degree
3
Width in number of modular spacings
1
Frequency
50/60 Hz
Degree of protection (IP)
IP20
Number of protected poles
1
Concurrently switching neutral conductor
no
Rated short-circuit breaking capacity according to IEC 60947-2
-
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
With interlocking device
no
Ambient temperature during operating
-15 - 60 °C
Flush-mounted installation
no
Number of poles (total)
2
Anti-nuisance tripping version
no
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1
10 kA
Disconnection characteristic
Undelayed
Rated short-circuit breaking capacity according to EN 61009
-
Downloads

Acti9 iC60H RCBO plug on neutral - 1P+Ns - 16A - C - 10000A - 30mA - type A
Product details
SKU Code: A9D05816
EAN Code: 3606481369291
Minimum order: 1
Good Availability (3 sellers)
Availability
317 In Stock
£107.28
16 In Stock
£154.24
Back Order Available to back order for despatch 30/05/2025
£148.38
Distributor | Availability | Price | |
---|---|---|---|
![]() |
317 In Stock | £107.28 Ex. VAT | |
![]() |
16 In Stock | £154.24 Ex. VAT | |
![]() |
Back Order Available to back order for despatch 30/05/2025 | £148.38 Ex. VAT |
Price Range:
£107.28 > £154.24 ex. vat
59 loyalty points
Technical Data
Main Features
Voltage type
AC
Built-in depth
72 mm
Rated current
16 A
Rated voltage
240 V
Release characteristic
C
Rated insulation voltage Ui
400 V
Rated fault current
0.03 A
Leakage current type
A
Surge current capacity
0.25 kA
Current limiting class
3
Over voltage category
2
Pollution degree
3
Width in number of modular spacings
1
Frequency
50/60 Hz
Degree of protection (IP)
IP20
Number of protected poles
1
Concurrently switching neutral conductor
no
Rated short-circuit breaking capacity according to IEC 60947-2
-
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
With interlocking device
no
Ambient temperature during operating
-15 - 60 °C
Flush-mounted installation
no
Number of poles (total)
2
Anti-nuisance tripping version
no
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1
10 kA
Disconnection characteristic
Undelayed
Rated short-circuit breaking capacity according to EN 61009
-
Downloads