Technical Data
Main Features
Voltage type
AC
Built-in depth
45 mm
Rated current
16 A
Rated voltage
240 V
Release characteristic
C
Rated insulation voltage Ui
400 V
Rated fault current
0.03 A
Leakage current type
A
Surge current capacity
0.25 kA
Current limiting class
3
Over voltage category
4
Pollution degree
3
Width in number of modular spacings
1
Frequency
50 Hz
Degree of protection (IP)
IP20
Number of protected poles
1
Concurrently switching neutral conductor
yes
Rated short-circuit breaking capacity according to IEC 60947-2
-
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
With interlocking device
no
Ambient temperature during operating
-15 - 60 °C
Flush-mounted installation
no
Number of poles (total)
2
Anti-nuisance tripping version
no
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1
10 kA
Disconnection characteristic
Undelayed
Rated short-circuit breaking capacity according to EN 61009
-
Downloads

iC60H - earth leakage circuit breaker - 1P + N - C curve - 16 A - 30 mA - 240 V
Product details
SKU Code: A9D11816
EAN Code: 3606480558610
Minimum order: 1
Good Availability (3 sellers)
Availability
618 In Stock
£102.24
6 In Stock
£105.84
Back Order Call for availability on 0345 030 60 80
£147.00
Distributor | Availability | Price | |
---|---|---|---|
![]() |
618 In Stock | £102.24 Ex. VAT | |
![]() |
6 In Stock | £105.84 Ex. VAT | |
![]() |
Back Order Call for availability on 0345 030 60 80 | £147.00 Ex. VAT |
Price Range:
£102.24 > £147.00 ex. vat
58 loyalty points
Technical Data
Main Features
Voltage type
AC
Built-in depth
45 mm
Rated current
16 A
Rated voltage
240 V
Release characteristic
C
Rated insulation voltage Ui
400 V
Rated fault current
0.03 A
Leakage current type
A
Surge current capacity
0.25 kA
Current limiting class
3
Over voltage category
4
Pollution degree
3
Width in number of modular spacings
1
Frequency
50 Hz
Degree of protection (IP)
IP20
Number of protected poles
1
Concurrently switching neutral conductor
yes
Rated short-circuit breaking capacity according to IEC 60947-2
-
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
With interlocking device
no
Ambient temperature during operating
-15 - 60 °C
Flush-mounted installation
no
Number of poles (total)
2
Anti-nuisance tripping version
no
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1
10 kA
Disconnection characteristic
Undelayed
Rated short-circuit breaking capacity according to EN 61009
-