Technical Data
Main Features
Voltage type
AC
Built-in depth
45 mm
Rated current
40 A
Rated voltage
240 V
Release characteristic
C
Rated insulation voltage Ui
400 V
Rated fault current
0.1 A
Leakage current type
A
Surge current capacity
0.25 kA
Current limiting class
3
Over voltage category
4
Pollution degree
3
Width in number of modular spacings
1
Frequency
50 Hz
Degree of protection (IP)
IP20
Number of protected poles
1
Concurrently switching neutral conductor
yes
Rated short-circuit breaking capacity according to IEC 60947-2
-
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
With interlocking device
no
Ambient temperature during operating
-15 - 60 °C
Flush-mounted installation
no
Number of poles (total)
2
Anti-nuisance tripping version
no
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1
10 kA
Disconnection characteristic
Undelayed
Rated short-circuit breaking capacity according to EN 61009
-
Downloads

iC60H - earth leakage circuit breaker - 1P + N - C curve - 40 A - 100 mA - 240 V
Product details
SKU Code: A9D12840
EAN Code: 3606480558498
Minimum order: 1
Some Availability (1 seller)
Availability
Out of Stock
£116.77
6 In Stock
£156.02
Distributor | Availability | Price | |
---|---|---|---|
![]() |
Out of Stock | £116.77 Ex. VAT | |
![]() |
6 In Stock | £156.02 Ex. VAT |
Price Range:
£116.77 > £156.02 ex. vat
64 loyalty points
Technical Data
Main Features
Voltage type
AC
Built-in depth
45 mm
Rated current
40 A
Rated voltage
240 V
Release characteristic
C
Rated insulation voltage Ui
400 V
Rated fault current
0.1 A
Leakage current type
A
Surge current capacity
0.25 kA
Current limiting class
3
Over voltage category
4
Pollution degree
3
Width in number of modular spacings
1
Frequency
50 Hz
Degree of protection (IP)
IP20
Number of protected poles
1
Concurrently switching neutral conductor
yes
Rated short-circuit breaking capacity according to IEC 60947-2
-
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
With interlocking device
no
Ambient temperature during operating
-15 - 60 °C
Flush-mounted installation
no
Number of poles (total)
2
Anti-nuisance tripping version
no
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1
10 kA
Disconnection characteristic
Undelayed
Rated short-circuit breaking capacity according to EN 61009
-
Downloads