Technical Data
Main Features
Voltage type
AC/DC
Built-in depth
44.5 mm
Rated current
6 A
Rated voltage
240 V
Frequency
50 - 60 Hz
Release characteristic
C
Rated insulation voltage Ui
500 V
Current limiting class
3
Over voltage category
4
Pollution degree
3
Width in number of modular spacings
1
Explosion-proof
no
Degree of protection (IP)
IP20
Number of protected poles
1
Concurrently switching neutral conductor
no
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
Ambient temperature during operating
-35 - 70 °C
Flush-mounted installation
no
Additional equipment possible
yes
Number of poles (total)
1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
15 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
-
Rated impulse withstand voltage Uimp
6 kV
Downloads

Acti9 iC60H 1P 6A C Miniature Circuit breaker
Product details
SKU Code: A9F54106
EAN Code: 3606480514715
Minimum order: 1
Good Availability (5 sellers)
Availability
11 In Stock
£14.93
166 In Stock
£19.38
510 In Stock
£19.38
27 In Stock
£26.92
8 In Stock
£25.90
Distributor | Availability | Price | |
---|---|---|---|
![]() |
11 In Stock | £14.93 Ex. VAT | |
![]() |
166 In Stock | £19.38 Ex. VAT | |
![]() |
510 In Stock | £19.38 Ex. VAT | |
![]() |
27 In Stock | £26.92 Ex. VAT | |
![]() |
8 In Stock | £25.90 Ex. VAT |
Price Range:
£14.93 > £26.92 ex. vat
10 loyalty points
Technical Data
Main Features
Voltage type
AC/DC
Built-in depth
44.5 mm
Rated current
6 A
Rated voltage
240 V
Frequency
50 - 60 Hz
Release characteristic
C
Rated insulation voltage Ui
500 V
Current limiting class
3
Over voltage category
4
Pollution degree
3
Width in number of modular spacings
1
Explosion-proof
no
Degree of protection (IP)
IP20
Number of protected poles
1
Concurrently switching neutral conductor
no
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
Ambient temperature during operating
-35 - 70 °C
Flush-mounted installation
no
Additional equipment possible
yes
Number of poles (total)
1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
-
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
15 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
-
Rated impulse withstand voltage Uimp
6 kV
Downloads