Technical Data
Main Features
Voltage type
AC/DC
Built-in depth
44.5 mm
Rated current
10 A
Rated voltage
415 V
Frequency
50 - 60 Hz
Release characteristic
D
Rated insulation voltage Ui
500 V
Current limiting class
3
Over voltage category
4
Pollution degree
3
Width in number of modular spacings
3
Explosion-proof
no
Degree of protection (IP)
IP20
Number of protected poles
3
Concurrently switching neutral conductor
no
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
Ambient temperature during operating
-35 - 70 °C
Flush-mounted installation
no
Additional equipment possible
yes
Number of poles (total)
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
10 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
30 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
Rated impulse withstand voltage Uimp
6 kV
Downloads

Acti9 iC60H 3P 10A D Miniature Circuit Breaker
Product details
SKU Code: A9F55310
EAN Code: 3606480515446
Minimum order: 1
Good Availability (6 sellers)
Availability
1 In Stock
£62.38
44 In Stock
£77.27
5 In Stock
£80.98
1 In Stock
£112.49
18 In Stock
£108.22
Back Order Manufacturer lead time of 5 weeks.
£109.46
Distributor | Availability | Price | |
---|---|---|---|
![]() |
1 In Stock | £62.38 Ex. VAT | |
![]() |
44 In Stock | £77.27 Ex. VAT | |
![]() |
5 In Stock | £80.98 Ex. VAT | |
![]() |
1 In Stock | £112.49 Ex. VAT | |
![]() |
18 In Stock | £108.22 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 5 weeks. | £109.46 Ex. VAT |
Price Range:
£62.38 > £112.49 ex. vat
43 loyalty points
Technical Data
Main Features
Voltage type
AC/DC
Built-in depth
44.5 mm
Rated current
10 A
Rated voltage
415 V
Frequency
50 - 60 Hz
Release characteristic
D
Rated insulation voltage Ui
500 V
Current limiting class
3
Over voltage category
4
Pollution degree
3
Width in number of modular spacings
3
Explosion-proof
no
Degree of protection (IP)
IP20
Number of protected poles
3
Concurrently switching neutral conductor
no
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 16 mm²
Ambient temperature during operating
-35 - 70 °C
Flush-mounted installation
no
Additional equipment possible
yes
Number of poles (total)
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
10 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
30 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
Rated impulse withstand voltage Uimp
6 kV
Downloads