Technical Data
Main Features
Voltage type
AC/DC
Built-in depth
44.5 mm
Rated current
50 A
Rated voltage
415 V
Frequency
50 - 60 Hz
Release characteristic
C
Rated insulation voltage Ui
500 V
Current limiting class
3
Over voltage category
4
Pollution degree
3
Width in number of modular spacings
3
Explosion-proof
no
Degree of protection (IP)
IP20
Number of protected poles
3
Concurrently switching neutral conductor
no
Connectable conductor cross section solid-core
1 - 35 mm²
Connectable conductor cross section multi-wired
1 - 25 mm²
Ambient temperature during operating
-35 - 70 °C
Flush-mounted installation
no
Additional equipment possible
yes
Number of poles (total)
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
10 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
30 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
Rated impulse withstand voltage Uimp
6 kV
Downloads

Acti9 iC60H 3P 50A C Miniature Circuit breaker
Product details
SKU Code: A9F54350
EAN Code: 3606480515026
Minimum order: 1
Good Availability (6 sellers)
Availability
1 In Stock
£73.36
27 In Stock
£94.17
9 In Stock
£95.25
Back Order Call for availability on 0345 030 60 80
£132.29
10 In Stock
£127.26
Back Order Manufacturer lead time of 5 weeks.
£128.72
Distributor | Availability | Price | |
---|---|---|---|
![]() |
1 In Stock | £73.36 Ex. VAT | |
![]() |
27 In Stock | £94.17 Ex. VAT | |
![]() |
9 In Stock | £95.25 Ex. VAT | |
![]() |
Back Order Call for availability on 0345 030 60 80 | £132.29 Ex. VAT | |
![]() |
10 In Stock | £127.26 Ex. VAT | |
![]() |
Back Order Manufacturer lead time of 5 weeks. | £128.72 Ex. VAT |
Price Range:
£73.36 > £132.29 ex. vat
50 loyalty points
Technical Data
Main Features
Voltage type
AC/DC
Built-in depth
44.5 mm
Rated current
50 A
Rated voltage
415 V
Frequency
50 - 60 Hz
Release characteristic
C
Rated insulation voltage Ui
500 V
Current limiting class
3
Over voltage category
4
Pollution degree
3
Width in number of modular spacings
3
Explosion-proof
no
Degree of protection (IP)
IP20
Number of protected poles
3
Concurrently switching neutral conductor
no
Connectable conductor cross section solid-core
1 - 35 mm²
Connectable conductor cross section multi-wired
1 - 25 mm²
Ambient temperature during operating
-35 - 70 °C
Flush-mounted installation
no
Additional equipment possible
yes
Number of poles (total)
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
10 kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
30 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
15 kA
Rated impulse withstand voltage Uimp
6 kV