Technical Data
Main Features
Number of auxiliary contacts as normally open contact
Number of auxiliary contacts as normally closed contact
Rated permanent current Iu
630 A
With integrated under voltage release
-
Number of poles
3
Overload release current setting
Number of auxiliary contacts as change-over contact
Rated voltage
690 - 690 V
Degree of protection (IP)
IP40
Position of connection for main current circuit
Front side
Motor drive integrated
no
Type of electrical connection of main circuit
Screw connection
Type of control element
Toggle
With switched-off indicator
yes
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz
50 kA
Adjustment range short-term delayed short-circuit release
Adjustment range undelayed short-circuit release
Suitable for DIN rail (top hat rail) mounting
no
Integrated earth fault protection
no
Motor drive optional
yes
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
no
Complete device with protection unit
no
Downloads

circuit breaker basic frame, ComPacT NSX630N, 50 kA at 415 VAC 50/60 Hz, 630 A, without trip unit, 3 poles
Product details
SKU Code: C63N3
EAN Code: 3606482002975
Minimum order: 1
Some Availability (2 sellers)
Availability
5 In Stock
£1,110.41
Back Order Available to back order for despatch 05/06/2025, delivery within 1 working days
£1,799.84
Distributor | Availability | Price | |
---|---|---|---|
![]() |
5 In Stock | £1,110.41 Ex. VAT | |
![]() |
Back Order Available to back order for despatch 05/06/2025, delivery within 1 working days | £1,799.84 Ex. VAT |
Price Range:
£1,110.41 > £1,799.84 ex. vat
576 loyalty points
Technical Data
Main Features
Number of auxiliary contacts as normally open contact
Number of auxiliary contacts as normally closed contact
Rated permanent current Iu
630 A
With integrated under voltage release
-
Number of poles
3
Overload release current setting
Number of auxiliary contacts as change-over contact
Rated voltage
690 - 690 V
Degree of protection (IP)
IP40
Position of connection for main current circuit
Front side
Motor drive integrated
no
Type of electrical connection of main circuit
Screw connection
Type of control element
Toggle
With switched-off indicator
yes
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz
50 kA
Adjustment range short-term delayed short-circuit release
Adjustment range undelayed short-circuit release
Suitable for DIN rail (top hat rail) mounting
no
Integrated earth fault protection
no
Motor drive optional
yes
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
no
Complete device with protection unit
no